FLIR CM83
Support Center

FLIR CM83

Go to Product Details Page

For Support
Please call 1300 729 987 or click here for support

For Service
Call 1300 729 987 or Submit RMA

Overview:
Warranty & RMA

Test & Measurement Warranty

Learn more
Resources:
Warranty: FLIR Global Test & Measurement Limited Lifetime Warranty
Download
Datasheet: FLIR CM8x Datasheet
Download
Selection Guide: Clamp Meter Selection Guide
Download
Specifications
Overview
Jaw Opening
37 mm (1.45", 1500MCM)
Warranty
Limited Lifetime
Compliance & Certifications
Certifications
CE, UL, FCC
Connections & Communications
Bluetooth range max
32 ft (10 m)
Measurement & Analysis
AC VFD Voltage
Range 1000 V / Basic Accuracy +/- 1%
AC/DC Current
Range 599.9 A Max / Basic Accuracy +/- 2%
AC/DC Voltage
Range 999.9 V Max / Basic Accuracy +/- 1% / 0.7%
Active Power
Range 9.999 kW to 599.9 kW, (10 V, 5 A min) / Basic Accuracy +/- 3%
Capacitance
Range 3.999 mF Max / Basic Accuracy +/- 1.9%
Category Rating
CAT IV-600V, CAT III-1000V
Continuity Threshold
Range 30 Ω / Basic Accuracy +/- 1%
Diode Test
Range 0.4 to 0.8 V / Basic Accuracy +/- 0.1V
Frequency
Range 20.00 Hz to 9.999 kHz / Basic Accuracy +/- 0.5%
Harmonics
Range 1st-25th Order / Basic Accuracy +/- 5%
Inrush Current
Range 599.9 ACA Max (Integration Time 100 ms) / Basic Accuracy +/- 3%
Resistance
Range 99.99 kΩ Max / Basic Accuracy +/- 1%
Total Harmonic Distortion
Range 0.0 to 99.9% / Basic Accuracy +/- 3%
Power
Battery type
6 x AAA